MAC AV-COFDM Manual do Utilizador Página 13

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 24
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 12
13
Signal settings/Service Management
4) To restore the default values click on the DEFAULT button in the lower part of the tab.
5) To congure the AV2 input, select the INPUT 2
tab. The information in the conguration options
and its meaning are completely identical to that
shown for INPUT 1.
Service Management
1) Select the SETTINGS menu and then the SERVICE MANAGEMENT submenu.
2) Select the SERVICE MANAGEMENT tab.
The SERVICE MANAGEMENT tab lets you view
and modify the services processed in the MAC
201unit.
J
OUTPUT SERVICES:
F
EDIT NAME: click on the icon to edit the
name of the service corresponding to each
input and save the LCN values.
F
SERVICES: displays the name of each
service.
F
TYPE: modies the type of service.
F
PIDS: click on the icon to view the PID for each service.
F
INFO: allows you to view and edit information on the service (summarised and
detailed descriptions).
F
INPUT: displays the input corresponding to each service.
F
STATUS: displays the status of each service.
F
BLOCKED: to block any of the services, click on the corresponding box.
F
LCN: displays the logical channel number. If the background is yellow it cannot be
modied.
J
OUTPUT BITRATE:
F
MODEL: displays the model of the unit.
F
MAX. BITRATE: displays the maximum binary data speed supported by the unit.
F
MIN. NULL: displays the minimum percentage of binary data in the output that
does not contain information.
F
ACT. NULL: displays the current percentage of binary data in the output that does
not contain information.
EN
Vista de página 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 23 24

Comentários a estes Manuais

Sem comentários